Designed for static, fixtured coating of elastomer parts, electronic circuits, medical components, tubing and other assemblies
The PTC Model 4000V has a unique, patented chamber design that makes it more efficient than conventional baffled chamber systems. By eliminating baffles, this system delivers more useable chamber volume and reduces the amount of raw material required, along with reduced need for maintenance and cleaning. Additionally, this chamber and fixture design enables extremely low coating thickness gradients across substrate surfaces and coatings of exceptional clarity and low dimer content. Several optional chamber sizes accommodate varying production needs. Modular design enables quick and easy separation of the generator from the chamber modules for efficient and economical coating of a variety of substrates.
Key
Features
- Utilizes PTC’s patented tangential flow coating technology for film uniformity and production economy
- Baffle-free design decreases Parylene dimer usage, reduces maintenance requirements and produces films of exceptional clarity and uniformity
- Vertical design for processing PCBs and other substrates
- Different chamber sizes available to meet customer production needs
- Multiple hinged doors for tool-free access and easy maintenance
- The 4000V is fully microprocessor controlled. Utilizing a user-friendly touch-screen HMI display (Human Machine Interface), the 4000V comes pre-programmed to cover a wide range of Parylene coating applications. The HMI also collects critical coating-run process data that can be viewed on the HMI screen in real-time and can be exported and analyzed off-line using a personal computer.
Chamber Dimensions: Four standard inside diameters can be combined with four standard heights for sixteen possible combinations. Custom configurations are available.
| Chamber Dimensions: |
Usable Inside Diameters: |
Usable Height: |
12" x 12"
18" x 18"
22" x 22"
26" x 26"
|
11” (279mm)
17” (432mm)
21” (533mm)
25” (635mm) |
12” (305mm)
18” (457mm)
22” (559mm)
26” (660mm) |
Cold Trap: The system can be configured with a two stage mechanical chiller or alternative cooling methods per customer specifications.
Vacuum System : Mechanical, direct drive, rotary vane pump 13.4 cfm or 20.9 cfm (23m3h-l or 35m3h-l) depending on size of chamber selected. Oil mist after filter is standard and 99% effective. Electropneumatic operation of control and vent valving are standard.
Minimum Floor Space Requirement : 8' x 10' (2.5m x 3m)
Electrical Requirements: 208 volts, three-phase, 4 or 5 wire and ground, 5 kW. CE compliant. International configurations available.
Weight: 700 lbs to 800 lbs (318 kg to 363 kg)

Standard size. Available to customer specifications.
PTC reserves the right to change specifications without notice.
For additional information or to place an order, call (800) 999-4942 or submit an Order Request form.
PTC 4000V Spare Parts
Part Number |
Description |
POS-12 |
Cold Trap O-Ring |
POB-31 |
16" Chamber O-Ring |
POB-26 |
FTS Chiller O-Ring |
POS-16 |
4.5" Vaporizer Door O-Ring |
POB-20 |
NW Clamp (25) 1-1/8" O-Ring |
POS-38 |
NW Clamp (50) O-Ring |
POS-24 |
Nylon Spacing Ring O-Ring |
POS-22 |
Rotary Seal O-Ring |
PQL-01 |
Quartz Liner |
PTT-01 |
Tube Tongs |
PBE-01 |
Brush Extension Rod |
PBE-02 |
Brush & Rod Complete |
PAW-01 |
Alan Wrench |
PWX-01 |
Wax |
PVG-01 |
Vacuum Grease (4 oz.) |
PVG-04 |
Vaccum Grease (14 oz.) |
PGG-01 |
Grease Gun |
PHV-01 |
Pump Oil (1gal.) |
PHP-01 |
2" Pre/Post Heater |
PHV-45-120 |
Vaporizer Heater 4.5" |
PHD-01 |
Door Heater |
PHG-01 |
Chamber Gauge Heater |
PVS-01 |
Vacuum Sensor Foreline |
PVS-02 |
DV-36 Gauge Tube |
PTB-P2 |
Pre/Post Thermocouple (K) |
PTB-G2 |
Gauge Tube Thermocouple (K) |
PTK-01 |
Furnance Thermocouple |
PDW-01 |
RTD (Door) |
PRV-01 |
RTD (Vaporizer) |
|